    Diagram depicting energy focusing in Bendix Mass SpectrometerBox 1- 1960s
 Schematic diagram depicting energy focusing in a Bendix Time-of-Flight Mass Spectrometer. The Time-of-Flight Mass Spectrometer (TOFMS) was the flagship analytical instrument of the Bendix Corporation. Mass spectrometry… 
- 
    Diagram depicting total output integrator time sequenceBox 1- 1960s
 Schematic diagram depicting the total output integrator time sequence of a Bendix Corporation Time-of-Flight Mass Spectrometer. The Time-of-Flight Mass Spectrometer (TOFMS) was the flagship analytical instrument of the… 
- 
    Thermal ionization spectrum diagramBox 1- 1960s
 Schematic diagram illustrating the thermal ionization spectrum of sodium and potassium. This diagram was likely produced using a Bendix Corporation thermal ionization probe, which, as part of the Bendix Time-of-Flight… 
- 
    Diagram depicting background spectrum reading for Bendix Mass SpectrometerBox 1- 1960s
 Schematic diagram depicting the typical background spectrum reading for a Bendix Time-of-Flight Mass Spectrometer with a thermal ionization probe in place. As part of the Bendix system, the thermal ionization probe… 
- 
    Diagram of Bendix Model 843T Thermal Ionization ProbeBox 1- 1960s
 Schematic diagram of a Bendix Model 843T Thermal Ionization Probe designed for use with the Bendix Time-of-Flight Mass Spectrometer. This surface ionization inlet system provided a means of creating ions for spectral… 
- 
    Diagram of Bendix Mass SpectrometerBox 1- 1970s
 Schematic diagram of a section of a Bendix Time-of-Flight Mass Spectrometer, with view of the shock tube, oscilloscope, and attachment for a Knudsen cell or direct inlet system. The diagram is captioned "versatility,"… 
- 
    Component of Bendix Mass SpectrometerBox 1- 1960s
 Close-up view of a component part, possibly a filament, of a Bendix Time-of-Flight Mass Spectrometer. A Fisher Scientific ruler is visible next to the component to indicate its size. The Time-of-Flight Mass Spectrometer… 
- 
    Bendix Knudsen Cell Inlet SystemBox 1- 1960s
 Interior view of the power supply of a Bendix Corporation Knudsen Cell Inlet System. Inlet systems are typically used to introduce samples into a mass spectrometer's ion source for analysis. The Knudsen Cell Inlet… 
- 
    2 itemsComponents of Bendix Model 843A Direct Inlet SystemBox 1- 1960s
 Two close-up views of the filament and crucible of a Bendix Model 843A Direct Inlet System. Inlet systems are typically used to introduce samples into a mass spectrometer's ion source for analysis. The Model 843A Direct… - Creator Of Work Bendix Corporation
- Subject Scientific apparatus and instruments, Spectrometer industry, Mass spectrometry, Bendix Corporation
 
- 
    Bendix Model 843A Direct Inlet SystemBox 1- 1960s
 Diagram of a Bendix Corporation Model 843A Direct Inlet System with view of assorted component parts, including a crucible, filament, vacuum system header, and sample probe. Inlet systems are typically used to introduce… - Creator Of Work Bendix Corporation
- Subject Scientific apparatus and instruments, Spectrometer industry, Mass spectrometry, Bendix Corporation
 
- 
    2 itemsIon source for Bendix Mass SpectrometerBox 1- 1960s
 Two views of the ion source for a Bendix Time-of-Flight Mass Spectrometer. One of four component parts of a mass spectrometer, the ion source produces a beam of particles characteristic of the sample material for… 
- 
    Switch panel for Bendix Mass SpectrometerBox 1- 1960s
 Close-up view of the switch panel for a Bendix Corporation Time-of-Flight Mass Spectrometer. The Time-of-Flight Mass Spectrometer (TOFMS) was the flagship analytical instrument of the Bendix Corporation. 
- 
    Chart recorder for Bendix Mass SpectrometerBox 1- 1960s
 General view of the back of a chart recorder for a Bendix Corporation Time-of-Flight Mass Spectrometer. The Time-of-Flight Mass Spectrometer (TOFMS) was the flagship analytical instrument of the Bendix Corporation. 
 …
- 
    Direct inlet probe system for Bendix Mass SpectrometerBox 1- 1960s
 General view of the direct inlet probe system designed for use with a Bendix Corporation Time-of-Flight Mass Spectrometer. Component parts of the system include a vacuum system header, filament, crucible, and sample… 
- 
    Bendix Magnetic Electron MultiplierBox 1- 1960s
 Close-up view of a Bendix Corporation Magnetic Electron Multiplier designed for use with the Bendix Time-of-Flight Mass Spectrometer. The Time-of-Flight Mass Spectrometer (TOFMS) was the flagship analytical instrument… 
- 
    2 itemsIon source for Bendix Mass SpectrometerBox 1- 1960s
 Close-up view of the ion source for a Bendix Time-of-Flight Mass Spectrometer. One of four component parts of a mass spectrometer, the ion source produces a beam of particles characteristic of the sample material for… 
- 
    Residual gas analyzer for Bendix Mass SpectrometerBox 1- 1960s
 General view of a residual gas analyzer designed for use with a Bendix Corporation Time-of-Flight Mass Spectrometer. Component parts of the analyzer include an ion source, drift tube, magnetic electron multiplier, and… 
- 
    Ion source for Bendix Mass SpectrometerBox 1- Circa 1971
 Detail view of a portion of the ion source for a Bendix Corporation Mass Spectrometer. One of four component parts of a mass spectrometer, the ion source produces a beam of particles characteristic of the sample… 
- 
    Main electronics chasis for Bendix Mass SpectrometerBox 1- Circa 1971
 General view of the interior of the main electronics chasis (enclosure) for a Bendix Corporation MA-2 Time-of-Flight Mass Spectrometer. The Time-of-Flight Mass Spectrometer (TOFMS) was the flagship analytical instrument… 
- 
    2 itemsIon source for Bendix Mass SpectrometerBox 1- Circa 1971
 General and detail views of the ion source for a Bendix Corporation Time-of-Flight Mass Spectrometer. One of four component parts of a mass spectrometer, the ion source produces a beam of particles characteristic of the… 
 
                     
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 